Wastewater treatment plant at District 7 Hospital, Ho Chi Minh

xu ly nuoc thai benh vien quan 7 min

NTS Engineering Co., Ltd. consults on solutions, designs and constructs the wastewater treatment system for District 7 Hospital. The system uses biological technology combined with MBR membrane filter, bringing high treatment efficiency. The output wastewater meets QCVN 28:2010/BTNMT, column B.

NTS Engineering Co., Ltd. has selected and applied MBR wastewater treatment technology for the wastewater treatment system for District 7 Hospital. The project ensures that all wastewater generated from medical and treatment activities is treated to meet QCVN 28:2010/BTNMT, column B.

The project requires advanced technological solutions, optimal design within a limited area. Here, the system operates continuously and stably to serve the needs of 24/7 medical activities. With extensive experience, NTS has implemented a highly effective wastewater treatment system, thereby helping the hospital develop sustainably.

Hình ảnh nhà máy xử lý nước thải y tế quận 7 đã được xây dựng và đi vào vận hành
Actual image at the medical wastewater treatment plant in District 7

Challenge

The wastewater treatment project at District 7 hospital has many challenges and requirements, especially:

  • The wastewater contains high levels of organic matter, pathogenic microorganisms and residual pharmaceuticals, requiring a specialized treatment process and meeting QCVN 28:2010/BTNMT standards to ensure absolute safety for the environment.
  • The installation space in the hospital is limited, so the treatment system needs to have a compact design but still ensure high efficiency.
  • The system needs to prevent odors from arising well, avoiding affecting other hospital activities.

Solution

NTS has chosen biological treatment technology as AAO technology combined with MBR for the wastewater treatment project of District 7 Hospital, ensuring the effective removal of organic substances, bacteria, and suspended solids.
The system is designed in a modular form, neatly installed in a limited space, easy to upgrade when the system needs to be expanded.
In addition, the system is also equipped with a biological deodorizing solution to control odors, ensuring the around environment is always clean and safe.

Analysis

Assessment of water quality and condition

Design

Plan and design appropriate systems

Deployment

Installation and operation of water treatment systems

Monitor

Regular system monitoring and maintenance

Results

The wastewater treatment plant has treated all domestic and medical wastewater generated in District 7 Hospital, specifically:

Items Value Unit

Capacit

300

m3/day.night

BOD Removal Efficiency

< 30

mg/L

COD Removal Efficiency

< 60

mg/L

Total Coliform

< 550

MPN/100ml

The system fully complies with QCVN 28:2010/BTNMT and helps reduce energy costs by more than 25%.

90%
BOD/COD
25%
Save energy

Project information

Location:
101 Nguyen Thi Thap Street, Tan Phu Ward, District 7, HCMC
Year:
2018
Technology:
AAO combined with MBR

Project data

300
m³/day.night
Capacit
3
months
Implementation time
20-30
years
System lifespan
90
%
Automation

You need advice?

Contact us for advice on water treatment solutions that suit your needs.

Contact now
Gọi điện Messenger Messenger Zalo Zalo